Search results for "Orthodontic anchorage procedures"

showing 10 items of 16 documents

Bone-to-implant contact of orthodontic implants in humans--a histomorphometric investigation

2008

The purpose of the present study was to evaluate the percentage of direct bone-to-implant contact (BIC) of orthodontic anchorage implants (Orthosystem) after active orthodontic treatment. Twenty orthodontic implants (diameter, 3.3 mm; length, 4 or 6 mm) were inserted for orthodontic anchorage in different anatomical regions of 18 adult patients (nine males, nine females) aged 18-63 years. Fifteen implants (one per patient) were placed in the mid-palatal area, one implant (one patient) in the retromolar area of the mandible, one in the retromolar area and the mid-palatal area (one patient), and two (bilaterally, one patient) in the zygomatic area. The duration of the unloaded healing period …

AdultDental Stress AnalysisMalePalate HardAdolescentDentistryOrthodonticsOrthodontics CorrectiveOsseointegrationYoung AdultOsseointegrationOrthodontic Anchorage ProceduresmedicineHumansDevice RemovalDental ImplantsOrthodonticsWound HealingAdult patientsbusiness.industryDental Implantation EndosseousMandibleMiddle Agedmedicine.diseaseOrthodontic Anchorage ProceduresBone to implant contactRetromolar areaFemaleImplantMalocclusionbusinessMalocclusionThe European Journal of Orthodontics
researchProduct

Anatomic site evaluation of the palatal bone for temporary orthodontic anchorage devices.

2008

: Objectives: The aim of the present study was to assess the micromorphologic characteristics of the palatal bone from an implantologic standpoint. Materials and Methods: The material consisted of tissue blocks of autopsy material from 22 subjects (18 males, three females) between 18 and 63 years of age. The specimens comprised the anterior median palatal region from 5 to 10 mm behind the incisive foramen. They were prepared in the transversal plane according to ground thin-section technology. The midpalatal area as well as an area of 3 mm bilateral to the midline were assessed, and a classification of quantitative palatal bone availability was developed. Results: The findings could be divi…

AdultMalePalate HardBone densityAdolescentDentistryAnatomic SiteSuture (anatomy)Orthodontic AppliancesCadaverBone DensityCadaverOrthodontic Anchorage ProceduresMedicineHumansIncisive foramenAgedOrthodonticsbusiness.industryDental Implantation EndosseousMiddle AgedClassificationTrabecular bonemedicine.anatomical_structureCompact boneCortical boneFemaleOral SurgerybusinessClinical oral implants research
researchProduct

Bone quality in the midpalate for temporary anchorage devices.

2009

Objective The aim of the present study was to quantitatively assess the bone quality of the palatal bone from an implantologic standpoint. Material and methods The material consisted of palatal tissue blocks of autopsy material from 22 subjects (19 male, three female), between 18 and 63 years of age. The specimens comprised the anterior part of median palate (APMP) from about 7 mm behind the incisive foramen (first premolar regions), the middle part of median palate (MPMP, second premolar region), and the posterior part of the median palate (PPMP, first molar region). They were prepared in the transversal plane using ground-thin-section technology. The midpalatal areas of the different part…

AdultMalePalate HardYounger ageBone densityAdolescentDentistryHard tissueMandibular first molarYoung AdultBone DensityBone Marrowparasitic diseasesBone qualityPremolarmedicineCadaverOrthodontic Anchorage ProceduresHumansIncisive foramenDental Implantsbusiness.industryAge FactorsCranial SuturesMiddle Agedmedicine.anatomical_structureFemaleOral SurgerybusinessBone volumeClinical oral implants research
researchProduct

Do palatal implants remain positionally stable under orthodontic load? A clinical radiologic study.

2009

Introduction The aim of this study was to determine the positional stability and success rate of palatally placed length-reduced temporary anchorage devices (LRTADs) (length, 4 or 6 mm). Methods Twenty-two patients (ages, 21-62 years; 14 women, 8 men) were enrolled in the study. Each received 1 LRTAD (Orthosystem, Straumann, Switzerland) placed in the midsagittal palate for multifunctional anchorage tasks. Standardized cephalograms were taken directly after implant placement and at the end of treatment to analyze any implant movements. The cephalometric tracings were superimposed on anterior nasal spine to posterior nasal spine in posterior nasal spine to analyze changes in implant angulati…

AdultMaleTime FactorsTooth Movement TechniquesCephalometryBone ScrewsDentistryOrthodonticsOsseointegrationWeight-BearingYoung AdultOsseointegrationmedicineOrthodontic Anchorage ProceduresHumansOrthodontic Appliance DesignLongitudinal StudiesOrthodonticsDental Implantsbusiness.industryPalateDental Implantation EndosseousAnterior nasal spineCraniometryMiddle Agedmedicine.diseaseOrthodontic Anchorage ProceduresRadiographymedicine.anatomical_structureMaxillaFemaleImplantStress MechanicalMalocclusionPosterior nasal spinebusinessMalocclusionAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
researchProduct

Experimental evidence of pharmacological management of anchorage in Orthodontics: A systematic review

2015

Introduction: Orthodontic anchorage is one of the most challenging aspects of Orthodontics. Preventing undesired movement of teeth could result in safer and less complicated orthodontic treatment. Recently, several reviews have been published about the effects of different molecules on bone physiology and the clinical side effects in Orthodontics. However, the effects of local application of these substances on the rate of orthodontic tooth movement have not been assessed.Objectives: The aim of this research was to analyze the scientific evidence published in the literature about the effects of different molecules on orthodontic anchorage.Methods: The literature was systematically reviewed …

Bone remodeling periodBisfosfonatosTooth Movement TechniquesMovimentação dentáriaPharmacological managementAnti-Inflammatory AgentsOsteoclastsPamidronateDentistryZoledronic AcidAntioxidantsLactonesMiceStilbenesOrthodontic Anchorage ProceduresMedicineAgentes anti-inflamatóriosSulfonesAnti-inflammatory agentsOrthodonticsDiphosphonatesOsteoprotegerinaImidazolesOrthodontic anchorage proceduresArticlesBisphosphonatesProcedimentos de ancoragem ortodônticaTooth movementInclusion and exclusion criteriaBone RemodelingTooth MobilityOral SurgeryDiclofenacMEDLINEOrthodonticsKappa indexInterferon-gammaAnimalsHumansbusiness.industryOsteoprotegerinBone physiologyIsoxazolesOrthodontic Anchorage ProceduresAcetylcysteineRatslcsh:RK1-715CelecoxibResveratrolTooth movementlcsh:DentistryClodronic Acidbusiness
researchProduct

Osseointegration of miniscrews: a histomorphometric evaluation.

2007

SUMMARY Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric fi ndings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of fi ve male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of…

Dental Stress AnalysisMaleTime FactorsBone ScrewsDentistryMandibleBone anchorhistomorphometryOsseointegrationStatistics NonparametricDogsImplants ExperimentalOsseointegrationIndependent samplesAlveolar ProcessOrthodontic Anchorage ProceduresMedicineAnimalsOrthodonticsMiniaturizationbusiness.industryAlveolar processBracketMandibleExperimental animalmedicine.anatomical_structureDental Stress Analysismini screwsEquipment FailurebusinessorthodonticsEuropean journal of orthodontics
researchProduct

Comparative analysis of numerical and experimental data of orthodontic mini-implants

2011

The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, …

Dental Stress AnalysisMaterials science9 mm caliberFinite Element AnalysisOrthodontics610 Medicine & health10067 Clinic for Orthodontics and Pediatric DentistryDisplacement (vector)Stress (mechanics)Imaging Three-DimensionalOrthodontic Anchorage ProceduresPerpendicularAnimalsOrthodontic Appliance DesignDental ImplantsModels Statisticalbusiness.industry3505 OrthodonticsBiomechanicsExperimental dataX-Ray MicrotomographyStructural engineeringFinite element methodBiomechanical PhenomenaCattleStress MechanicalbusinessRotation (mathematics)
researchProduct

Primary loading of palatal implants for orthodontic anchorage--a pilot animal study.

2006

Summary Objectives This study aimed at evaluating the clinical performance and osseointegration of short orthodontic implants immediately loaded with orthodontic forces. Material and methods The investigation was designed as an experimental animal study. Eight palatal implants of the Ortho-system® were immediately loaded with 100 cN after palatal insertion in 4 female german shepherd dogs. Xylene orange and calcein green were used for polychrome sequential labelling. Histological preparation utilized the cutting and grinding technique. Outcome variables were clinical implant success, histological osseointegration and bone-to-implant contact rates. Results All (8/8) implants were clinically …

Dental Stress AnalysisPalate HardTime FactorsDentistryPilot ProjectsDevice implantOsseointegrationDogsImplants ExperimentalOsseointegrationOrthodontic Anchorage ProceduresMedicineAnimalsAnimal studyBone formationbusiness.industryClinical performanceAppositionBone to implant contactOtorhinolaryngologyMicroscopy FluorescenceSurgeryFemaleImplantOral SurgerybusinessJournal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery
researchProduct

Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

2013

Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bott…

Insertion torqueDental Stress Analysisprimary stabilityArtificial boneMaterials scienceorthodontic mini-implantsTorsion MechanicalOdontologíatorsional fractureProsthesis Designpullout strengthDesign characteristicslaw.inventionMecànica de fracturalawRisk FactorsMaterials TestingBiomaterials and Bioengineering in DentistrymedicineOrthodontic Anchorage ProceduresFracture mechanicsGeneral Dentistry:Enginyeria dels materials::Desgast de materials [Àrees temàtiques de la UPC]Implants artificialsTorsion (mechanics)Implants ArtificialPullout strength:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludProsthesis Failuremedicine.anatomical_structureOtorhinolaryngologyMini implantsUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningSurgeryResearch-ArticleElectron microscopeCancellous boneinsertion torqueBiomedical engineering
researchProduct

Orthodontic load on short maxillary implants with reduced sink depth: an experimental study.

2008

Objective The aim of this study was to investigate experimentally the positional stability and histomorphometric findings of length-reduced temporary anchorage devices (Orthosystem, length: 4 mm) with reduced sink depth. Material and methods For this purpose, four maxillary pre-molars ((2)P(2), (3)P(3)) were extracted from each of four foxhounds. After a 16-week alveolar healing period, 16 implants (four per dog) were inserted into the edentulous areas. Four implants (one per dog) were placed simultaneously in the mid-palatal area. The implants were intentionally submerged to about three-quarters of their length. After a 10-week unloaded implant healing period, the implants in the P3 areas …

MaleImplant surfaceTime FactorsSurface PropertiesBone ScrewsDentistryBone contactDogsOrthodontic AppliancesBone MarrowOsseointegrationAlveolar ProcessMaxillaOrthodontic Anchorage ProceduresOrthodontic WiresMedicineAnimalsOrthodontic Appliance DesignBicuspidDental ImplantsOrthodontic wireOrthodontic Appliance Designbusiness.industryPalateBone screwsEquipment failureMaxillaEquipment FailureImplantBone RemodelingStress MechanicalOral SurgerybusinessClinical oral implants research
researchProduct